Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Journal of Southern Medical University ; (12): 151-156, 2021.
Article in Chinese | WPRIM | ID: wpr-880843

ABSTRACT

OBJECTIVE@#To explore the feasibility of detecting maternal hereditary mitochondrial tRNA@*METHODS@#We performed sequence analysis of mitochondrial DNA in blood samples from 2070 cases of maternal hereditary mitochondrial disease in the First Affiliated Hospital of Wenzhou Medical University, and identified 3 patients with m.15927G>A mutation.Buccal swabs and blood samples were obtained from the 3 patients (mutation group) and 3 normal volunteers (control group).After extracting whole genomic DNA from all the samples, the DNA concentration and purity were analyzed.The PCR products were subjected to dot blot hybridization, Southern blot hybridization, and DNA sequencing analysis to verify the feasibility of detecting m.15927G>A mutation using buccal swabs.@*RESULTS@#There was no significant difference in DNA concentration extracted from buccal swabs and blood samples in either the mutation group or the control group (@*CONCLUSIONS@#Buccal swabs collection accurate is an accurate and sensitive method for the detection of m.15927G>A mutation.


Subject(s)
Humans , DNA, Mitochondrial/genetics , Mitochondria , Mutation , RNA, Transfer , Sequence Analysis, DNA
2.
Organ Transplantation ; (6): 155-2021.
Article in Chinese | WPRIM | ID: wpr-873725

ABSTRACT

A large quantity of studies related to renal transplantation were reviewed to extract and summarize the international frontier hot spots and difficulties, new transplantation technologies, new methods, new visions and new progress on renal transplantation in 2020.The main contents included rejection, optimization application and regulation of immunosuppression, transplant infection, malignancy after transplantation, non-invasive detection and biomarkers, donor organ preservation, repair and utilization, recurrence of renal disease after renal transplantation, multi-factors affecting long-term survival of transplant kidney, computer and artificial intelligence, etc.Strengthening the reading and thinking of literatures in the field of renal transplantation and broadening horizons in higher starting piont, combined with clinical practice of renal transplantation in China, help to promote the long-term efficacy of renal transplantation.

3.
Journal of Biomedical Engineering ; (6): 342-350, 2021.
Article in Chinese | WPRIM | ID: wpr-879283

ABSTRACT

The use of non-invasive blood glucose detection techniques can help diabetic patients to alleviate the pain of intrusive detection, reduce the cost of detection, and achieve real-time monitoring and effective control of blood glucose. Given the existing limitations of the minimally invasive or invasive blood glucose detection methods, such as low detection accuracy, high cost and complex operation, and the laser source's wavelength and cost, this paper, based on the non-invasive blood glucose detector developed by the research group, designs a non-invasive blood glucose detection method. It is founded on dual-wavelength near-infrared light diffuse reflection by using the 1 550 nm near-infrared light as measuring light to collect blood glucose information and the 1 310 nm near-infrared light as reference light to remove the effects of water molecules in the blood. Fourteen volunteers were recruited for


Subject(s)
Humans , Blood Glucose , Diabetes Mellitus , Nonlinear Dynamics
4.
Chinese Journal of Medical Instrumentation ; (6): 384-389, 2020.
Article in Chinese | WPRIM | ID: wpr-942746

ABSTRACT

To satisfy the daily demand of skin condition maintenance, make non-invasive real-time detection, and get proper quantitative evaluation of skin viscoelasticity parameters at the same time, a portable non-invasive detection system to acquire real-time skin tissue viscoelasticity is developed. The system relies mainly on a single-degree-of-freedom forced vibration model, with spring-damp-mass, and on dynamic micro indentation method. The experiment is conducted on two kinds of springs, and on pigskin tissues as well, the system's suitability, accuracy and stability are confirmed. The skin viscoelasticity detection in vivo is also carried out on 20 subjects with different ages, the differences of skin viscoelasticity in various parts of the body are investigated, and the correlations between age and skin viscoelasticity are clarified.


Subject(s)
Humans , Elasticity , Skin , Skin Physiological Phenomena , Time , Viscosity
5.
Chinese Journal of Gastroenterology ; (12): 307-310, 2019.
Article in Chinese | WPRIM | ID: wpr-861836

ABSTRACT

Helicobacter pylori (Hp) infection is associated with multiple digestive tract diseases. At present, the diagnostic methods of Hp are divided mainly into invasive detection and non-invasive detection. Different diagnostic methods have their advantages and disadvantages. This article reviewed the diagnostic methods and its evaluation of Hp.

6.
Chinese Journal of Analytical Chemistry ; (12): 1291-1296, 2017.
Article in Chinese | WPRIM | ID: wpr-609374

ABSTRACT

To facilitate noninvasive diagnosis of anemia, high-performance and portable near infrared (NIR) spectrometer for human blood constituents was designed and fabricated based on linear variable filter (LVF).Meanwhile, the performance of support vector regression (SVR) model for quantitative analysis of human hemoglobin (Hb) was investigated.Spectral data were collected noninvasively from 100 volunteers by self-designed LVF-NIR spectrometer, then divided into calibration set, validation set 1 and 2.To establish a robust SVR model, grid search method was applied to optimize the penalty parameter and kernel function parameter c=5.28, g=0.33.Then, Hb levels in the validation 1 and 2 sets were quantitatively analyzed.The results showed that the root mean square error of prediction (RMSEP) were 10.20 g/L and 10.85 g/L, respectively, and the relative RMSEP (R-RMSEP) were 6.85% and 7.48%, respectively.The results indicated that the SVR model had high prediction accuracy to Hb level and adaptability to different samples, and could satisfy the requirements of clinical measurement.Based on the SVR algorithm, the self-designed LVF-NIR spectrometer has a wide application prospect in the field of non-invasive anemia diagnosis.

7.
Journal of Medical Biomechanics ; (6): E468-E473, 2015.
Article in Chinese | WPRIM | ID: wpr-804464

ABSTRACT

There contains so much physiological/pathological information in pulse wave, which can reflect the early changes in cardiovascular function parameters. Therefore, it would be valuable to quantify the information revealed by pulse wave as important reference for cardiovascular diseases. In this review, the relationship between physiological/pathological information in cardiovascular system and pulse wave was described from the viewpoint of pulse wave formation mechanism, and to explain how the non-invasive detection indexes supplied by pulse wave could be applied in clinical use by analyzing the waveforms. Cardiovascular health evaluation index established by physiological/pathological information from cardiovascular system with pulse wave theory was also discussed. The development of non-invasive detection methods for cardiovascular system based on pulse wave theory can contribute to cardiovascular health care and provide important reference for the early detection, early prevention and early treatment of cardiovascular diseases. Besides, the non-invasive detection method can simplify the process of clinical testing and reduce the costs so as to achieve health assessment on cardiovascular diseases timely and reduce the mortality and disability rates.

8.
Journal of Medical Biomechanics ; (6): E554-E559, 2014.
Article in Chinese | WPRIM | ID: wpr-804335

ABSTRACT

Objective To detect the blood viscosity values and find out the statistically significant influencing factors of blood viscosity and their fitting formulas among the middle aged and elderly people with high incidence of cardiovascular diseases. Methods The subjects’ blood was collected in the hospital, together with their physiological and pathological information, and LG-R-80 series rotary viscometer detector was used to detect blood viscosity. The statistically significant factors of blood viscosity and their fitting formulas were obtained by using SPSS. Results Blood viscosity increased with age and body mass index (BMI) and reached its peak value in 60 year-old males (5.35 mPa•s) and 50 year-old females (4.45 mPa•s), respectively, then the variation of blood viscosity would be stabilized, with no more increase; the blood viscosity values of males in all groups with different ages were significantly higher than those of females, with difference value in the range of 0.28-0.90 mPa•s; the blood viscosity values were obviously higher in hypertension group than those in normal group, with statistically significant differences (P<0.1). Conclusions The blood viscosity distribution in people with high incidence of cardiovascular diseases has certain regular pattern, and the obtained fitting formula between blood viscosity and influencing factors in this study would provide useful references for further study such as variation of blood viscosity under different physiological conditions, effects of different viscosities on some cardiovascular diseases, and non-invasive detection of blood viscosities.

9.
Chinese Journal of Blood Transfusion ; (12)2001.
Article in Chinese | WPRIM | ID: wpr-582823

ABSTRACT

Objective To establish the FCM method of non invasive detection of fetal ABO and Rh(D) blood groups in maternal blood.Methods Using absorption and elution method, we obtained the IgG anti A and anti B from human sera. The IgG anti A, B, D were used as the first antibody to react with RBCs in maternal peripheral blood.The goat anti human IgG F(ab')2 FITC was used as the second antibody to conjugate anti A, B, D antibodies, Meanwhile anti i PE was used to mark fetal RBCs in maternal peripheral blood.The fluorescence dot plot diagrams of maternal and fetal cells acquired by FCM were used to detect fetal ABO and Rh(D) blood groups.Results Peripheral blood from 69 pregnant women between 8 and 39 weeks of gestation were studied.Fetal cells could not be found in 13 samples.Of the remaining 56 samples,fetal red cells were identified successfully with ABO/Rh(D) blood types identical to those tested after the birth of the baby.Conclusion In women with fetomaternal hemorrhage(FMH) during pregnancy,the FCM method established by the author can accurately and non invasively detect the blood groups of fetuses.This method can possibly be used for diagnosis of hemolytic disease of the newborn.

10.
Chinese Medical Equipment Journal ; (6)1989.
Article in Chinese | WPRIM | ID: wpr-584492

ABSTRACT

The definition, principle, characteristics of micropower Ultra-Wide-Band (UWB) radar are described and discussed in this paper. The human subject is experimented using the UWB radar developed by our team. The experimental results show that UWB radar is able to detect the life signals of the human subject such as respiration and heartbeat without any sensor and electrode touching the subject.The radar can be applied to non-invasive detection of life signals.

SELECTION OF CITATIONS
SEARCH DETAIL